ELECTROMAGNETIC FLOWMETER APLISENS MODEL PEM-1000

119/55A Đường Phan Văn Hùm, Phường Trung Mỹ Tây, Thành phố Hồ Chí Minh
Hotline: 0962543178
Email: info@ctmarkvn.com

ELECTROMAGNETIC FLOWMETER APLISENS MODEL PEM-1000

Nhà sản xuất: APLISENS

  • Liên hệ
  • 42

Application

Electromagnetic flowmeter for bidirectional measurement of liquids with a minimum conductivity of 5 μS/cm:

• Acid, alkalis

• Paints

• Pastes

• Water, wastewater, etc.

Measuring system

The measuring system consists of a transmitter and a sensor.

Two versions are available:

• Compact version: Transmitter and sensor form a mechanical unit

PEM-1000ALW

• Remote version: Sensor is mounted separate from the transmitter

PEM-1000NW

Technical data

Specification for PEM-1000 control unit

Electrical conductivity of the medium _ 5_S/cm

Input resistance _ 1010_

Accuracy _0,5% of reading at 20_100% Q10m/s

special version: _0,2% of reading at 20_100% Q10m/s

(for reference conditions)*

Low flow rejection adjustable, any value

Actual flow both directions (l/s,m3/h, m3/s, other)

Totalizer 3 counters: total, positive, negative (m3, other)

Configuration LCD display/buttons or Modbus RTU via RS485

Empty pipe detection cyclic, configurable

Analog output 4_20mA/500_

active output (passive output – on request)

Pulse/frequency output max. 24V/10mA DC

0,1…2000Hz in frequency mode

up to 500Hz in pulse mode

2-state output OC 2, open collector, max. 35V DC for each

galvanic insulation, reverse polarity protection

Communication output Modbus RTU/RS 485

galvanic insulation

2-state input 5…35V DC/2mA

passive input, galvanic insulation, reverse polarity protection

Power supply 90..260V AC/50Hz/15VA

10…36V DC/15W (reverse polarity protection)

Protection class IP66 (IP67 on request)

Ambient temperature -20…60°C

Weight 3,5kg

 

Specification for PEM-1000 sensor

Nominal size DN10_1000 / ANSI 0,5”…40”

Max. static pressure

standard: 1,6MPa (2,5MPa, 4MPa on request)

Process connection flange DIN, ANSI

Ambient temperature -20_60_C

Liner temperature range Rubber: -5_90_C

Neoprene: 0_80_C

Teflon PTFE: -25_90_C (special version -25_130_C)

PFA: -10_90_C

Connection cable standard: 8m (other on request)

Electrodes material 316L           

(Hastelloy/Tantalum)

Liner Hard rubber DN40_1000

Neoprene DN40_1000

Teflon PTFE DN15_500

PFA DN10

Casing and flange material standard : carbon steel

Rustproofing paint

Excitation coils supply from the transmitter

Excitation of coils isolation class E

Protection class standard: IP67, (IP68 on request)

Measuring principle electromagnetic

Accessories grounding rings