ĐỒNG HỒ ĐO ÁP SUẤT DẠNG MÀNG CÓ TIẾP ĐIỂM ĐIỆN WIKA PGS43.160

119/55A Đường Phan Văn Hùm, Phường Trung Mỹ Tây, Thành phố Hồ Chí Minh
Hotline: 0962543178
Email: info@ctmarkvn.com

ĐỒNG HỒ ĐO ÁP SUẤT DẠNG MÀNG CÓ TIẾP ĐIỂM ĐIỆN WIKA PGS43.160

Diaphragm pressure gauge with switch contacts
For the process industry, high overload safety up to the 10-fold full scale value, max. 40 bar
Nhà sản xuất: WIKA

  • Liên hệ
  • 2744

Applications

* Control and regulation of industrial processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar

* Monitoring of plants and switching of electric circuits

* For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience

* Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction

Special Features

* High reliability and long service life

* Wide choice of special materials

* Up to 4 switch contacts per instrument

Also available with liquid filling for high dynamic pressure loads or vibrations

* Instruments with inductive contacts for use in hazardous areas

* Instruments with contacts for PLC applications

Specifications
Standard:
      EN 837-3: Diaphragm and capsule pressure gauges 
      DIN 16085: Pressure gauges with electrical limit contact devices 
Other version:
      Oil- and grease-free
      Oil- and grease-free for oxygen
      Silicone-free
      Per NACE 1) MR0175 / ISO 15156, use in H₂S-containing environments in oil and gas production
      Per NACE 1) MR0103 / ISO 17945, metals resistant to hydrogen sulphide stress cracking
      With pre-volume deflagration flame arrester 2) for mounting to zone 0 (EPL Ga); model 910.21, see data sheet AC 91.02
      Diaphragm pressure gauge with output signal, models PGT43.100, PGT43.160; see data sheet PV 14.03
      Diaphragm pressure gauge, high overload safety; models 43x.x6, PGx43HP, see data sheets PM 04.07, PV 24.07 and PV 14.07
      With flushing bore on the open connecting flange
Nominal size (NS): Ø 100 mm [4"], Ø 160 mm [6"]
Window: Laminated safety glass, Polycarbonate 
Case Design:
      Safety level “S1” per EN 837-1: With blow-out device
      Safety level “S3” per EN 837-1: With solid baffle wall and blow-out back 
Case Material: Stainless steel 1.4301 (304), Stainless steel 1.4571 (316Ti)
Case filling: Without, Silicone oil 
Movement: Stainless steel
Type of measuring element: Diaphragm element
Materials (wetted):
      Diaphragm element: Span ≤ 0.25 bar - Stainless steel 316L
                                              Span ≥ 0.4 bar - NiCr alloy (Inconel)
      Coating / Lining: Without, PTFE, Hastelloy, Monel, Tantalum, Gold (only for diaphragm element) Further materials on request
Accuracy class: 1.6, 2.5
Temperature error: On deviation from the reference conditions at the measuring system: ≤ ±0.8 %/10 K of respective full scale value
Switch hysteresis: Depending on the type of contact used, see from page 7
Reference conditions: Ambient temperature +20 °C [+68 °F]
Unit: bar, psi, mbar, kg/cm², MPa,  kPa Other units on request 
Overload safety: 
      5 x full scale value, max. 40 bar
      10 x full scale value, max. 40 bar
Vacuum resistance: Without, Vacuum-resistant to -1 bar 
Dial Scale layout: Single scale, Dual scale 
Dial Scale colour:
       Single scale: Black
      Dual scale: Black/red
Dial Material: Aluminium 
Instrument pointer: Aluminium, black 
Set pointer →See type of contact, from page 7
Process connection
Standard:
EN 837,  ANSI / ASME B1.20.1, ASME B16.5, EN 1092-1, form B
Size: 
      EN 837: G 1/2 B, M20 x 1.5 
      ANSI / ASME B1.20.1: 1/2 NPT
      ASME B16.5: Open connecting flange 1" class 150, RF, Open connecting flange 2" class 150, RF, Open connecting flange 1" class 300, RF
      EN 1092-1, form B: Open connecting flange DN 25 PN 40, Open connecting flange DN 50 PN 40
Materials (wetted)
Diaphragm element: Span ≤ 0.25 bar - Stainless steel 316L
                                    Span ≥ 0.4 bar - NiCr alloy (Inconel)
Process connection with lower measuring flange: Stainless steel 316L
Coating / Lining: Without, PTFE, Hastelloy, Monel, Tantalum, Gold (only for diaphragm element) 
Seal: FPM/FKM, PTFE
Output signal
Type of contact:

      Magnetic snap-action contact, model 821 (→ See page 8)
      Inductive contact, model 831 (→ See page 9)
      Electronic contact, model 830 E (→ See page 10)
      Reed switch, model 851 (→ See page 11) 
Switch technology
Magnetic snap-action contact, model 821: 

      No control unit and no supply voltage required
      Direct switching up to 250 V, 1 A 
Inductive contact, model 831:
      Suitable for use in hazardous areas with corresponding control unit (model 904. xx)
      Long service life due to non-contact switching
      Low influence on the indication accuracy
      Fail-safe switching at high switching frequency
      Insensitive to corrosion
      Also available in safety version 
Electronic contact, model 830 E:
      For direct triggering of a programmable logic controller (PLC)
      Long service life due to non-contact switching
      Low influence on the indication accuracy
      Fail-safe switching at high switching frequency
      Insensitive to corrosion 
Reed switch, model 851:
      No control unit and no supply voltage required
      Direct switching up to 250 V, 1 A
      For direct triggering of a programmable logic controller (PLC)
      Wear-free, as non-contact 
Contact setting:
      Contact(s) adjustable, adjustment key attached to cable socket
      Contact(s) fixed, without adjustment lock 1)
      Adjustment lock sealable (tamper-proof)
      Adjustment lock sealed (tamper-proof) 1)
      Captive adjustment key with the adjustment lock connected