Communication
Level probes with communication protocol RS485/Modbus RTU. The communication standard for data interchange with the transmitter is the RS485/Modbus RTU. Communication with the transmitter is carried out with PC using RS converter and Aplisens software.
Technical data*
Metrological parameters
Accuracy Ł ±0,1%
Long-term stability Ł accuracy for 3 years
(for nominal range)
Thermal error < ±0,1% (FSO) / 10°C
max ±0,4% (FSO) in the whole
compensation range
Thermal compensation range. -25...80°C (other range on request)
Additional electronic damping 0...30 s
Electrical parameters
Power supply in Modbus mode: 4…28 V DC
Exia version: 4…10 V DC in 4…20mA mode
(only non Exia version): 5..28 V DC
Transmission range 1200 m
Output MODBUS RTU + 4..20 mA
Address space 1...247 devices address
Transmission speed 600...115200 bps
Parity transmission no parity, odd, even
frame transmission 10...11 bit (1, 2 bit-stop)
*more information about technical data available in user’s manual
Special version
Teflon – teflon cable shieldin